| Assessment Year | 1994 |
|---|---|
| Principal Product | Ground contact cultivating tools |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
38,000
ft2
|
| Annual Production | 2,000,000
pieces
|
| Production Hrs. Annual | 2,280
hrs
|
| Location (State) | Colorado |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $53,800 | 683,763 |
kWh
|
$0.079 |
| Natural Gas | $73,600 | 23,291 |
MMBtu
|
$3.16 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,210 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2414: Use waste heat from hot flue gases to preheat | $4,230 | $15,000 | - |
$4,230
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $1,700 | $4,490 |
$1,700
21,688
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,110 | $2,970 |
$1,110
14,068
kWh
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $400 | $50 |
$400
5,275
kWh
|
- | |
| TOTAL RECOMMENDED | $7,440 | $22,510 |
$3,210
41,031
kWh
|
$4,230
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $3,210 | $7,510 |
$3,210
41,031
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs