Assessment Year | 1996 |
---|---|
Principal Product | Compressed Air Dryers and Filters |
NAICS |
n/a
|
SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
Sales Range | $10 M to 50M |
# of Employees | 113 |
Plant Area |
75,000
ft2
|
Annual Production | 3,960
pieces
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $49,141 | 1,374,853 |
kWh
|
$0.036 |
Electricity Demand | $16,967 | 3,619 |
kW-mo/yr
|
$4.69 |
Electricity Fees | $5,319 | - |
|
- |
Natural Gas | $13,973 | 2,586 |
MMBtu
|
$5.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $25,207 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,677 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,723 | $2,483 |
$1,723
45,721
kWh
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $1,292 | $3,720 |
$1,292
34,291
kWh
|
- | - | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $494 | $400 |
$494
12,896
kWh
|
- | - | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,347 | $35 |
$1,347
35,756
kWh
|
- | - | - | |
05 | 2.4314: Use synthetic lubricant | $360 | $775 |
$360
9,379
kWh
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $557 | $85 |
$557
14,654
kWh
|
- | - | - | |
07 | 2.7243: Improve air circulation with destratification fans / other methods | $1,461 | $2,640 |
$(-121.0)
(-3,224)
kWh
|
$1,582
-
MMBtu
|
- | - | |
08 | 2.7221: Lower temperature during the winter season and vice-versa | $2,970 | $690 | - |
$2,970
-
MMBtu
|
- | - | |
09 | 2.6218: Turn off equipment when not in use | $1,145 | - |
$290
7,620
kWh
|
$855
-
MMBtu
|
- | - | |
10 | 2.7444: Close holes and openings in building such as broken windows | $418 | $486 | - |
$418
-
MMBtu
|
- | - | |
11 | 2.7444: Close holes and openings in building such as broken windows | $183 | $212 | - |
$183
-
MMBtu
|
- | - | |
12 | 3.4111: Use closed cycle process to minimize waste water production | $8,969 | $8,075 | - | - |
$8,969
-
Tgal
|
- | |
13 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $4,288 | $3,900 | - | - | - |
$4,288
-
lb
|
|
TOTAL RECOMMENDED | $25,207 | $23,501 |
$5,942
157,093
kWh
|
$6,008
-
MMBtu
|
$8,969
-
Tgal
|
$4,288
-
lb
|
||
TOTAL IMPLEMENTED | $13,677 | $11,714 |
$5,146
136,284
kWh
|
$4,243
-
MMBtu
|
- |
$4,288
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs