Assessment Year | 1994 |
---|---|
Principal Product | Barges |
NAICS |
n/a
|
SIC | 3732: Boat Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 283 |
Plant Area |
200,000
ft2
|
Annual Production | 153
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $338,089 | 6,619,285 |
kWh
|
$0.051 |
Natural Gas | $153,704 | 24,523 |
MMBtu
|
$6.27 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,278 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $31,263 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $977 | $4,304 |
$977
25,205
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $73 | $482 |
$73
1,758
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $762 | $21,980 |
$762
19,637
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $28,727 | $750 |
$28,727
744,431
kWh
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $189 | $220 |
$189
5,569
kWh
|
- | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $5,572 | $3,600 | - |
$5,572
-
MMBtu
|
|
07 | 2.3212: Optimize plant power factor | $5,004 | $13,195 |
$5,004
-
kWh
|
- | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $7,634 | $1,000 |
$7,634
197,831
kWh
|
- | |
09 | 2.7261: Install timers and/or thermostats | $4,403 | $275 |
$4,403
128,664
kWh
|
- | |
10 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $724 | - |
$724
21,102
kWh
|
- | |
11 | 2.2437: Recover waste heat from equipment | $213 | $250 | - |
$213
-
MMBtu
|
|
TOTAL RECOMMENDED | $54,278 | $46,056 |
$48,493
1,144,197
kWh
|
$5,785
-
MMBtu
|
||
TOTAL IMPLEMENTED | $31,263 | $27,516 |
$31,263
812,133
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs