Assessment Year 1994
Principal Product Barges
NAICS
n/a
SIC 3732: Boat Building and Repairing
Sales Range $10
M
to 50
M
# of Employees 283
Plant Area 200,000
ft2
Annual Production 153
pieces
Production Hrs. Annual 6,120
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $338,089 6,619,285
kWh
Natural Gas $153,704 24,523
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $54,278 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $31,263

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $977 $4,304 $977
25,205
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $73 $482 $73
1,758
kWh
-
03 2.4133: Use most efficient type of electric motors $762 $21,980 $762
19,637
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $28,727 $750 $28,727
744,431
kWh
-
05 2.4221: Install compressor air intakes in coolest locations $189 $220 $189
5,569
kWh
-
06 2.7243: Improve air circulation with destratification fans / other methods $5,572 $3,600 - $5,572
-
MMBtu
07 2.3212: Optimize plant power factor $5,004 $13,195 $5,004
-
kWh
-
08 2.7111: Reduce illumination to minimum necessary levels $7,634 $1,000 $7,634
197,831
kWh
-
09 2.7261: Install timers and/or thermostats $4,403 $275 $4,403
128,664
kWh
-
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $724 - $724
21,102
kWh
-
11 2.2437: Recover waste heat from equipment $213 $250 - $213
-
MMBtu
TOTAL RECOMMENDED $54,278 $46,056 $48,493
1,144,197
kWh
$5,785
-
MMBtu
TOTAL IMPLEMENTED $31,263 $27,516 $31,263
812,133
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs