Assessment Year | 1994 |
---|---|
Principal Product | Plastic Product |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
29,500
ft2
|
Annual Production | 10,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $134,982 | 2,012,603 |
kWh
|
$0.067 |
Natural Gas | $433 | 65 |
MMBtu
|
$6.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,165 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,187 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.6218: Turn off equipment when not in use | $9,187 | - |
$9,187
143,318
kWh
|
|
02 | 2.2511: Insulate bare equipment | $8,319 | $129 |
$8,319
131,887
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $7,000 | $8,050 |
$7,000
111,079
kWh
|
|
04 | 2.4323: Use optimum size and capacity equipment | $2,284 | $22,000 |
$2,284
31,653
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $795 | $238 |
$795
12,016
kWh
|
|
06 | 2.4221: Install compressor air intakes in coolest locations | $580 | $310 |
$580
9,379
kWh
|
|
TOTAL RECOMMENDED | $28,165 | $30,727 |
$28,165
439,332
kWh
|
||
TOTAL IMPLEMENTED | $9,187 | - |
$9,187
143,318
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs