Assessment Year | 1994 |
---|---|
Principal Product | PVC Siding |
NAICS |
n/a
|
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
147,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 8,568
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $443,031 | 10,788,687 |
kWh
|
$0.041 |
Natural Gas | $42,785 | 7,371 |
MMBtu
|
$5.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $28,469 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $27,033 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $688 | $1,882 |
$688
26,377
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $1,303 | $42,700 |
$1,303
50,117
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $899 | $364 |
$899
21,688
kWh
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $133 | $293 | - |
$133
-
MMBtu
|
|
05 | 2.2511: Insulate bare equipment | $25,446 | $4,329 |
$25,446
978,605
kWh
|
- | |
TOTAL RECOMMENDED | $28,469 | $49,568 |
$28,336
1,076,787
kWh
|
$133
-
MMBtu
|
||
TOTAL IMPLEMENTED | $27,033 | $6,575 |
$27,033
1,026,670
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs