| Assessment Year | 1994 |
|---|---|
| Principal Product | Cardboard and Cardboard Boxes |
| NAICS |
n/a
|
| SIC | 2653: Corrugated and Solid Fiber Boxes |
| Sales Range | $5 M to 10M |
| # of Employees | 65 |
| Plant Area |
85,140
ft2
|
| Annual Production | 93,600
thousand feet
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $94,791 | 2,017,292 |
kWh
|
$0.047 |
| Natural Gas | $96,935 | 35,377 |
MMBtu
|
$2.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,534 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,083 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $838 | $1,474 |
$838
26,084
kWh
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $247 | $8,480 |
$247
7,620
kWh
|
- | |
| 03 | 2.7444: Close holes and openings in building such as broken windows | $2,064 | $1,800 | - |
$2,064
-
MMBtu
|
|
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,520 | $1,190 | - |
$2,520
-
MMBtu
|
|
| 05 | 2.7444: Close holes and openings in building such as broken windows | $1,378 | $380 | - |
$1,378
-
MMBtu
|
|
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,528 | $900 | - |
$1,528
-
MMBtu
|
|
| 07 | 2.2136: Install / repair insulation on steam lines | $730 | $329 | - |
$730
-
MMBtu
|
|
| 08 | 2.4221: Install compressor air intakes in coolest locations | $265 | $285 |
$265
8,206
kWh
|
- | |
| 09 | 2.6218: Turn off equipment when not in use | $220 | - |
$113
3,517
kWh
|
$107
-
MMBtu
|
|
| 10 | 2.1213: Direct warmest air to combustion intake | $6,565 | $2,090 | - |
$6,565
-
MMBtu
|
|
| 11 | 2.6218: Turn off equipment when not in use | $938 | $190 |
$938
29,015
kWh
|
- | |
| 12 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $241 | - |
$241
7,620
kWh
|
- | |
| TOTAL RECOMMENDED | $17,534 | $17,118 |
$2,642
82,062
kWh
|
$14,892
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $6,083 | $12,373 |
$1,198
37,221
kWh
|
$4,885
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs