Assessment Year | 1993 |
---|---|
Principal Product | Automobile Glass |
NAICS |
n/a
|
SIC | 3231: Glass Products, Made of Purchased Glass |
Sales Range | $10 M to 50M |
# of Employees | 168 |
Plant Area |
186,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $582,116 | 9,943,435 |
kWh
|
$0.059 |
Natural Gas | $97,141 | 23,707 |
MMBtu
|
$4.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,882 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,499 | $1,000 |
$1,499
68,875
kWh
|
- | |
02 | 2.7243: Improve air circulation with destratification fans / other methods | $6,130 | $5,200 | - |
$6,130
-
MMBtu
|
|
03 | 2.2511: Insulate bare equipment | $2,655 | $2,837 | - |
$2,655
-
MMBtu
|
|
04 | 2.2414: Use waste heat from hot flue gases to preheat | $167 | $340 | - |
$167
-
MMBtu
|
|
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $356 | $777 | - |
$356
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $201 | $5,827 |
$201
9,379
kWh
|
- | |
07 | 2.4133: Use most efficient type of electric motors | $182 | $11,930 |
$182
8,206
kWh
|
- | |
TOTAL RECOMMENDED | $11,190 | $27,911 |
$1,882
86,460
kWh
|
$9,308
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,882 | $18,757 |
$1,882
86,460
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs