Assessment Year | 2024 |
---|---|
Principal Product | Used Medical Devices and Equipment |
NAICS | 334510: Electromedical and Electrotherapeutic Apparatus Manufacturing |
SIC | 3845: Electromedical and Electrotherapeutic Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
300,000
ft2
|
Annual Production | 5,000
units
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $187,331 | 2,714,407 |
kWh
|
$0.069 | |
Electricity Demand | $138,703 | 7,574 |
kW-mo/yr
|
$18.31 | |
Electricity Fees | $18,264 | - |
|
- | |
Natural Gas | $44,814 | 7,092 |
MMBtu
|
$6.32 | |
Waste Disposal Costs | |||||
Water Usage | $4,574 | 1,082 |
Tgal
|
$4.23 | |
Water Disposal | $4,574 | 1,082 |
Tgal
|
$4.23 | |
TOTAL YEARLY COSTS | $398,260 | ||||
RECOMMENDED SAVINGS* | $52,209 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $31,974 | $246,400 |
$25,049
363,043
kWh
|
$6,925
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $7,290 | - |
$3,311
47,981
kWh
|
$3,979
-
kW-mo/yr
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $6,027 | $9,016 |
$(-519.0)
7,522
kWh
|
- |
$6,546
-
MMBtu
|
|
04 | 2.7444: Close holes and openings in building such as broken windows | $5,832 | $2,000 | - | - |
$5,832
-
MMBtu
|
|
05 | 2.7261: Install timers and/or thermostats | $835 | $198 |
$835
12,096
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $251 | $460 |
$251
3,633
kWh
|
- | - | |
TOTAL RECOMMENDED | $52,209 | $258,074 |
$28,926
434,275
kWh
|
$10,905
-
kW-mo/yr
|
$12,378
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs