ITAC Assessment: WM0208
ITAC logo
ITAC Assessment: WM0208
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product snow removal truck attachments
NAICS 333120: Construction Machinery Manufacturing
SIC 3531: Construction Machinery and Equipment
Sales Range $500
k
to 1
M
# of Employees 300
Plant Area 177,000
ft2
Annual Production 55,000
units
Production Hrs. Annual 8,400
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $389,789 5,866,104
kWh
Electricity Demand $262,479 16,416
kW-mo/yr
Electricity Fees $95,714 -
Natural Gas $279,561 63,100
MMBtu
Waste Disposal Costs
Water Usage $13,284 3,232
Tgal
TOTAL YEARLY COSTS $1,040,827
RECOMMENDED SAVINGS* $62,975 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $17,906

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4226: Use / purchase optimum sized compressor $37,878 $122,100 $28,141
426,376
kWh
$9,737
-
kW-mo/yr
-
02 2.7447: Install vinyl strip / high speed / air curtain doors $9,702 $8,700 - - $9,702
-
MMBtu
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,761 $1,950 $4,280
64,484
kWh
$1,481
-
kW-mo/yr
-
04 2.7224: Reduce space conditioning during non-working hours $3,796 - $2,214
33,551
kWh
- $1,582
-
MMBtu
05 2.4227: Use compressor air filters $3,395 $4,786 $2,522
38,213
kWh
$873
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,014 $4,664 $1,633
24,743
kWh
$381
-
kW-mo/yr
-
07 2.7444: Close holes and openings in building such as broken windows $430 $700 - - $430
-
MMBtu
TOTAL RECOMMENDED $62,975 $142,900 $38,790
587,367
kWh
$12,471
-
kW-mo/yr
$11,714
-
MMBtu
TOTAL IMPLEMENTED $17,906 $16,014 $5,913
89,227
kWh
$1,861
-
kW-mo/yr
$10,132
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs