Assessment Year | 2023 |
---|---|
Principal Product | Flow Wrapper Machines |
NAICS | 333993: Packaging Machinery Manufacturing |
SIC | 3565: Packaging Machinery |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
80,000
ft2
|
Annual Production | 50
units
|
Production Hrs. Annual | 3,840
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $44,755 | 877,040 |
kWh
|
$0.051 | |
Electricity Demand | $36,347 | 3,300 |
kW-mo/yr
|
$11.01 | |
Electricity Fees | $16,564 | - |
|
- | |
Natural Gas | $43,409 | 5,256 |
MMBtu
|
$8.26 | |
Waste Disposal Costs | |||||
Water Usage | $2,591 | 184 |
Tgal
|
$14.08 | |
Water Disposal | $2,591 | 184 |
Tgal
|
$14.08 | |
TOTAL YEARLY COSTS | $146,257 | ||||
RECOMMENDED SAVINGS* | $12,579 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $5,577 | - |
$830
16,283
kWh
|
$997
-
kW-mo/yr
|
$3,750
-
MMBtu
|
|
02 | 2.7231: Use radiant heater for spot heating | $3,501 | $13,280 | - | - |
$3,501
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,309 | $1,827 |
$781
15,322
kWh
|
$528
-
kW-mo/yr
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $690 | $3,044 |
$562
11,020
kWh
|
$128
-
kW-mo/yr
|
- | |
05 | 2.4227: Use compressor air filters | $595 | $2,789 |
$493
9,665
kWh
|
$102
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $540 | $148 |
$355
6,967
kWh
|
$185
-
kW-mo/yr
|
- | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $367 | $240 | - | - |
$367
-
MMBtu
|
|
TOTAL RECOMMENDED | $12,579 | $21,328 |
$3,022
59,257
kWh
|
$1,940
-
kW-mo/yr
|
$7,618
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs