| Assessment Year | 2023 |
|---|---|
| Principal Product | Flow Wrapper Machines |
| NAICS | 333993: Packaging Machinery Manufacturing |
| SIC | 3565: Packaging Machinery |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
80,000
ft2
|
| Annual Production | 50
units
|
| Production Hrs. Annual | 3,840
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $44,755 | 877,040 |
kWh
|
$0.051 | |
| Electricity Demand | $36,347 | 3,300 |
kW-mo/yr
|
$11.01 | |
| Electricity Fees | $16,564 | - |
|
- | |
| Natural Gas | $43,409 | 5,256 |
MMBtu
|
$8.26 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,591 | 184 |
Tgal
|
$14.08 | |
| Water Disposal | $2,591 | 184 |
Tgal
|
$14.08 | |
| TOTAL YEARLY COSTS | $146,257 | ||||
| RECOMMENDED SAVINGS* | $12,579 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7224: Reduce space conditioning during non-working hours | $5,577 | - |
$830
16,283
kWh
|
$997
-
kW-mo/yr
|
$3,750
-
MMBtu
|
|
| 02 | 2.7231: Use radiant heater for spot heating | $3,501 | $13,280 | - | - |
$3,501
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,309 | $1,827 |
$781
15,322
kWh
|
$528
-
kW-mo/yr
|
- | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $690 | $3,044 |
$562
11,020
kWh
|
$128
-
kW-mo/yr
|
- | |
| 05 | 2.4227: Use compressor air filters | $595 | $2,789 |
$493
9,665
kWh
|
$102
-
kW-mo/yr
|
- | |
| 06 | 2.7135: Install occupancy sensors | $540 | $148 |
$355
6,967
kWh
|
$185
-
kW-mo/yr
|
- | |
| 07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $367 | $240 | - | - |
$367
-
MMBtu
|
|
| TOTAL RECOMMENDED | $12,579 | $21,328 |
$3,022
59,257
kWh
|
$1,940
-
kW-mo/yr
|
$7,618
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs