Assessment Year | 2012 |
---|---|
Principal Product | Storm doors and windows |
NAICS | 332321: Metal Window and Door Manufacturing |
SIC | 3442: Metal Doors, Sash, Frames, Molding, and Trim Manufacturing |
Sales Range | $10 M to 50M |
# of Employees | 260 |
Plant Area |
134,517
ft2
|
Annual Production | 600,000
pieces
|
Production Hrs. Annual | 3,402
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $85,809 | 2,429,000 |
kWh
|
$0.035 |
Electricity Demand | $42,360 | 7,130 |
kW-mo/yr
|
$5.94 |
Natural Gas | $18,041 | 2,869 |
MMBtu
|
$6.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,412 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,943 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,645 | $19,693 |
$2,914
82,806
kWh
|
$1,731
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $333 | $478 |
$333
9,482
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,882 | $1,500 |
$3,691
104,850
kWh
|
$2,191
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $4,416 | $1,260 | - | - |
$4,416
-
MMBtu
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $2,136 | $1,440 |
$1,394
39,596
kWh
|
$742
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $17,412 | $24,371 |
$8,332
236,734
kWh
|
$4,664
-
kW-mo/yr
|
$4,416
-
MMBtu
|
||
TOTAL IMPLEMENTED | $14,943 | $22,453 |
$6,605
187,656
kWh
|
$3,922
-
kW-mo/yr
|
$4,416
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs