Assessment Year | 2023 |
---|---|
Principal Product | Manufacturing of Conveyors |
NAICS | 333922: Conveyor and Conveying Equipment Manufacturing |
SIC | 3535: Conveyors and Conveying Equipment |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
100,000
ft2
|
Annual Production | 1,537
units
|
Production Hrs. Annual | 5,824
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $47,609 | 1,019,760 |
kWh
|
$0.047 | |
Electricity Demand | $31,764 | 2,939 |
kW-mo/yr
|
$10.81 | |
Electricity Fees | $18,092 | - |
|
- | |
Natural Gas | $38,577 | 6,071 |
MMBtu
|
$6.35 | |
Waste Disposal Costs | |||||
Water Usage | $16,500 | 276 |
Tgal
|
$59.78 | |
TOTAL YEARLY COSTS | $152,542 | ||||
RECOMMENDED SAVINGS* | $15,196 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $9,546 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $4,554 | $9,300 |
$(-447.0)
9,503
kWh
|
- |
$5,001
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,356 | $9,386 |
$1,872
39,836
kWh
|
$2,484
-
kW-mo/yr
|
- | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $3,671 | - | - | - |
$3,671
-
MMBtu
|
|
04 | 2.7444: Close holes and openings in building such as broken windows | $1,383 | $193 | - | - |
$1,383
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $860 | $2,040 |
$425
9,053
kWh
|
$434
-
kW-mo/yr
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $236 | $650 |
$161
3,421
kWh
|
$76
-
kW-mo/yr
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $136 | - |
$102
2,172
kWh
|
$34
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $15,196 | $21,569 |
$2,114
63,985
kWh
|
$3,028
-
kW-mo/yr
|
$10,055
-
MMBtu
|
||
TOTAL IMPLEMENTED | $9,546 | $9,579 |
$1,974
42,008
kWh
|
$2,517
-
kW-mo/yr
|
$5,054
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs