Assessment Year | 2019 |
---|---|
Principal Product | Flexible Packaging |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 77 |
Plant Area |
86,000
ft2
|
Annual Production | 100
ton
|
Production Hrs. Annual | 6,264
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $209,151 | 2,777,205 |
kWh
|
$0.075 | |
Electricity Demand | $36,470 | 4,291 |
kW-mo/yr
|
$8.50 | |
Natural Gas | $47,169 | 9,627 |
MMBtu
|
$4.90 | |
Waste Disposal Costs | |||||
Water Usage | $1,965 | 319 |
Tgal
|
$6.15 | |
TOTAL YEARLY COSTS | $294,755 | ||||
RECOMMENDED SAVINGS* | $76,786 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $10,477 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2442: Preheat combustion air with waste heat | $23,863 | $21,000 | - | - | - |
$23,863
-
MMBtu
|
|
02 | 2.9114: Use solar heat to make electricty | $21,662 | $106,000 |
$21,662
276,867
kWh
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,757 | - |
$5,035
66,847
kWh
|
$723
-
kW-mo/yr
|
- | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,118 | $5,000 |
$4,545
60,362
kWh
|
$573
-
kW-mo/yr
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,478 | $8,880 |
$3,046
40,569
kWh
|
$432
-
kW-mo/yr
|
- | - | |
06 | 2.7444: Close holes and openings in building such as broken windows | $3,158 | $1,365 | - | - | - |
$3,158
-
MMBtu
|
|
07 | 2.7231: Use radiant heater for spot heating | $3,041 | $2,800 | - | - | - |
$3,041
-
MMBtu
|
|
08 | 2.7135: Install occupancy sensors | $1,718 | $2,325 |
$1,718
22,812
kWh
|
- | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $1,616 | $3,900 |
$1,414
18,768
kWh
|
$202
-
kW-mo/yr
|
- | - | |
10 | 2.7444: Close holes and openings in building such as broken windows | $1,409 | $1,750 | - | - | - |
$1,409
-
MMBtu
|
|
11 | 2.3132: Recharge batteries on during off-peak demand periods | $1,396 | - | - | - | $1,396 | - | |
12 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,320 | $2,340 |
$1,118
14,838
kWh
|
$202
-
kW-mo/yr
|
- | - | |
13 | 2.7221: Lower temperature during the winter season and vice-versa | $1,087 | - |
$484
6,402
kWh
|
$604
-
kW-mo/yr
|
- | - | |
14 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $805 | $1,664 |
$697
9,250
kWh
|
$108
-
kW-mo/yr
|
- | - | |
15 | 2.4231: Reduce the pressure of compressed air to the minimum required | $741 | $970 |
$741
9,884
kWh
|
- | - | - | |
16 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $617 | $1,175 |
$617
8,193
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $76,786 | $159,169 |
$41,076
534,792
kWh
|
$2,843
-
kW-mo/yr
|
$1,396 |
$31,471
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,477 | $8,029 |
$5,242
69,612
kWh
|
$681
-
kW-mo/yr
|
$1,396 |
$3,158
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs