Assessment Year | 2019 |
---|---|
Principal Product | footwear |
NAICS | 316210: Footwear Manufacturing |
SIC | 3149: Footwear, Except Rubber, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
1,100,000
ft2
|
Annual Production | 3,000,000
units
|
Production Hrs. Annual | 3,640
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $231,483 | 3,375,080 |
kWh
|
$0.069 | |
Electricity Demand | $129,825 | 9,408 |
kW-mo/yr
|
$13.80 | |
Electricity Fees | $31,985 | - |
|
- | |
Natural Gas | $76,936 | 14,026 |
MMBtu
|
$5.49 | |
Waste Disposal Costs | |||||
Water Usage | $51,161 | 717 |
Tgal
|
$71.35 | |
TOTAL YEARLY COSTS | $521,390 | ||||
RECOMMENDED SAVINGS* | $39,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $19,242 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $19,750 | $28,500 |
$11,874
173,118
kWh
|
$7,876
-
kW-mo/yr
|
- | - | - | |
02 | 2.7231: Use radiant heater for spot heating | $7,329 | $9,450 | - | - | - |
$7,329
-
MMBtu
|
- | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,679 | $6,540 | - | - | - |
$4,679
-
MMBtu
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,469 | $3,500 |
$2,687
39,173
kWh
|
$1,782
-
kW-mo/yr
|
- | - | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $1,795 | $2,700 | - | - | $1,795 | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $619 | $1,160 |
$348
5,081
kWh
|
$97
-
kW-mo/yr
|
- | - | $174 | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $418 | $750 |
$252
3,666
kWh
|
$166
-
kW-mo/yr
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $351 | $1,115 |
$162
2,371
kWh
|
$189
-
kW-mo/yr
|
- | - | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $258 | $1,370 |
$155
2,261
kWh
|
$103
-
kW-mo/yr
|
- | - | - | |
10 | 2.7134: Use photocell controls | $103 | $201 |
$103
1,502
kWh
|
- | - | - | - | |
TOTAL RECOMMENDED | $39,771 | $55,286 |
$15,583
227,172
kWh
|
$10,211
-
kW-mo/yr
|
$1,795 |
$12,008
-
MMBtu
|
$174 | ||
TOTAL IMPLEMENTED | $19,242 | $24,465 |
$3,197
46,625
kWh
|
$2,067
-
kW-mo/yr
|
$1,795 |
$12,008
-
MMBtu
|
$174 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs