Assessment Year | 2019 |
---|---|
Principal Product | Cookware |
NAICS | 332215: Metal Kitchen Cookware, Utensil, Cutlery, and Flatware (except Precious) Manufacturing |
SIC | 3365: Aluminum Foundries |
Sales Range | $50 M to 100M |
# of Employees | 160 |
Plant Area |
550,000
ft2
|
Annual Production | 650,000
units
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $530,399 | 8,242,437 |
kWh
|
$0.064 | |
Electricity Demand | $425,209 | 31,453 |
kW-mo/yr
|
$13.52 | |
Electricity Fees | $16,683 | - |
|
- | |
Natural Gas | $254,035 | 51,745 |
MMBtu
|
$4.91 | |
Waste Disposal Costs | |||||
Water Usage | $250,494 | 34,280 |
Tgal
|
$7.31 | |
TOTAL YEARLY COSTS | $1,476,820 | ||||
RECOMMENDED SAVINGS* | $51,660 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $18,166 | $70,712 |
$18,166
276,867
kWh
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $13,318 | $20,000 |
$9,826
154,967
kWh
|
$3,492
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $5,856 | $1,728 |
$4,356
68,613
kWh
|
$1,500
-
kW-mo/yr
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $5,059 | $1,610 | - | - |
$5,059
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,990 | $9,800 |
$3,683
58,009
kWh
|
$1,307
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $3,406 | $690 |
$3,406
53,647
kWh
|
- | - | |
07 | 2.7447: Install vinyl strip / high speed / air curtain doors | $865 | $164 | - | - |
$865
-
MMBtu
|
|
TOTAL RECOMMENDED | $51,660 | $104,704 |
$39,436
612,103
kWh
|
$6,300
-
kW-mo/yr
|
$5,924
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs