Assessment Year | 1997 |
---|---|
Principal Product | Lamp Processing |
NAICS |
n/a
|
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
28,000
ft2
|
Annual Production | 500,000
pieces
|
Production Hrs. Annual | 3,750
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,883 | 2,783,412 |
kWh
|
$0.038 |
Electricity Demand | $24,362 | 15,036 |
kW-mo/yr
|
$1.62 |
Natural Gas | $134,283 | 28,094 |
MMBtu
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,646 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,936 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $6,916 | $5,640 | - | - |
$6,916
-
MMBtu
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,875 | $4,543 |
$1,679
44,256
kWh
|
$196
-
kW-mo/yr
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $647 | $986 |
$647
16,999
kWh
|
- | - | - | - | |
04 | 3.4151: Minimize water usage | $471 | $150 | - | - | - | - |
$471
-
Tgal
|
|
05 | 2.2136: Install / repair insulation on steam lines | $252 | $305 | - | - |
$252
-
MMBtu
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $239 | $500 |
$208
5,569
kWh
|
$31
-
kW-mo/yr
|
- | - | - | |
07 | 3.4151: Minimize water usage | $193 | $400 | - | - | - | - |
$193
-
Tgal
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $123 | $192 |
$110
2,931
kWh
|
$13
-
kW-mo/yr
|
- | - | - | |
09 | 3.4157: Replace water cooling on processes with air cooling | $161 | $345 | - | - | - | - |
$161
-
Tgal
|
|
10 | 2.4314: Use synthetic lubricant | $160 | $315 |
$160
4,103
kWh
|
$39
-
kW-mo/yr
|
- | $(-39.0) | - | |
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $153 | $212 |
$120
3,224
kWh
|
$33
-
kW-mo/yr
|
- | - | - | |
12 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $456 | $700 |
$378
9,965
kWh
|
$78
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $11,646 | $14,288 |
$3,302
87,047
kWh
|
$390
-
kW-mo/yr
|
$7,168
-
MMBtu
|
$(-39.0) |
$825
-
Tgal
|
||
TOTAL IMPLEMENTED | $10,936 | $13,638 |
$3,094
81,478
kWh
|
$359
-
kW-mo/yr
|
$7,168
-
MMBtu
|
$(-39.0) |
$354
-
Tgal
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs