Assessment Year 2018
Principal Product Stair Lifts
NAICS 333921: Elevator and Moving Stairway Manufacturing
SIC 3534: Elevators and Moving Stairways
Sales Range $100
M
to 500
M
# of Employees 334
Plant Area 75,000
ft2
Annual Production 9,700
units
Production Hrs. Annual 5,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $206,740 2,856,190
kWh
Electricity Demand $68,927 7,702
kW-mo/yr
Electricity Fees $28,863 -
Natural Gas $34,657 5,662
MMBtu
Waste Disposal Costs
Water Usage $11,757 1,364
Tgal
TOTAL YEARLY COSTS $350,944
RECOMMENDED SAVINGS* $80,646 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $48,274

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $26,391 $22,752 $19,698
272,180
kWh
$6,693
-
kW-mo/yr
-
02 2.9114: Use solar heat to make electricty $20,855 $48,500 $20,855
276,867
kWh
- -
03 2.7447: Install vinyl strip / high speed / air curtain doors $9,244 $6,840 - - $9,244
-
MMBtu
04 2.4239: Eliminate or reduce compressed air usage $9,118 $19,300 $9,118
125,970
kWh
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,496 $2,000 $6,011
83,034
kWh
$1,485
-
kW-mo/yr
-
06 2.7221: Lower temperature during the winter season and vice-versa $2,084 - $1,610
22,241
kWh
$474
-
kW-mo/yr
-
07 2.7231: Use radiant heater for spot heating $1,744 $5,250 - - $1,744
-
MMBtu
08 2.7446: Utilize sensors controlling roof and wall openings $1,291 $533 - - $1,291
-
MMBtu
09 2.4221: Install compressor air intakes in coolest locations $804 $1,172 $554
7,585
kWh
$250
-
kW-mo/yr
-
10 2.7135: Install occupancy sensors $765 $600 $765
10,574
kWh
- -
11 2.7447: Install vinyl strip / high speed / air curtain doors $637 $740 - - $637
-
MMBtu
12 2.4111: Utilize energy-efficient belts and other improved mechanisms $217 $200 $163
2,266
kWh
$54
-
kW-mo/yr
-
TOTAL RECOMMENDED $80,646 $107,887 $58,774
800,717
kWh
$8,956
-
kW-mo/yr
$12,916
-
MMBtu
TOTAL IMPLEMENTED $48,274 $51,214 $36,991
511,010
kWh
$8,902
-
kW-mo/yr
$2,381
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs