Assessment Year | 2014 |
---|---|
Principal Product | cookware |
NAICS | 335210: Small Electrical Appliance Manufacturing |
SIC | 3634: Electric Housewares and Fans |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
145,000
ft2
|
Annual Production | 1,599,930
lb
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,467 | 811,700 |
kWh
|
$0.062 |
Electricity Demand | $30,419 | 4,056 |
kW-mo/yr
|
$7.50 |
Electricity Fees | $6,557 | - |
|
- |
Natural Gas | $57,056 | 9,503 |
MMBtu
|
$6.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,487 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,485 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.5131: Recycle white water | $6,827 | $13,958 | - | - | - |
$4,016
-
Tgal
|
$2,811
-
Tgal
|
- | |
02 | 2.4239: Eliminate or reduce compressed air usage | $2,114 | $2,500 |
$1,299
18,827
kWh
|
$815
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4224: Upgrade controls on compressors | $2,701 | - |
$1,660
24,051
kWh
|
$1,041
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,111 | $2,030 | - | - |
$1,111
-
MMBtu
|
- | - | - | |
05 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,440 | $940 | - | - |
$1,440
-
MMBtu
|
- | - | - | |
06 | 4.424: Improve space comfort conditioning | $4,160 | $350 | - | - | - | - | - | $4,160 | |
07 | 2.7111: Reduce illumination to minimum necessary levels | $478 | $280 |
$302
4,077
kWh
|
$176
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $313 | $630 |
$61
884
kWh
|
$252
-
kW-mo/yr
|
- | - | - | - | |
09 | 2.2514: Cover open tanks | $51 | - | - | - |
$51
-
MMBtu
|
- | - | - | |
10 | 2.2136: Install / repair insulation on steam lines | $38 | $100 | - | - |
$38
-
MMBtu
|
- | - | - | |
11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,255 | $1,220 |
$1,255
18,195
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $20,487 | $22,008 |
$4,577
66,034
kWh
|
$2,284
-
kW-mo/yr
|
$2,640
-
MMBtu
|
$4,016
-
Tgal
|
$2,811
-
Tgal
|
$4,160 | ||
TOTAL IMPLEMENTED | $4,485 | $1,500 |
$3,217
46,323
kWh
|
$1,217
-
kW-mo/yr
|
$51
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Water Consumption Savings | Increase in Production Savings |