| Assessment Year | 2014 |
|---|---|
| Principal Product | wireforms and stamping |
| NAICS | 332618: Other Fabricated Wire Product Manufacturing |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
80,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 5,228
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $43,868 | 685,440 |
kWh
|
$0.064 |
| Electricity Demand | $22,253 | 2,618 |
kW-mo/yr
|
$8.50 |
| Natural Gas | $15,959 | 3,071 |
MMBtu
|
$5.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $14,393 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,958 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,700 | $16,042 |
$3,581
55,967
kWh
|
$1,119
-
kW-mo/yr
|
- | |
| 02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $172 | $73 | - | - |
$172
-
MMBtu
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,678 | $1,768 |
$5,678
84,329
kWh
|
- | - | |
| 04 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $622 | $500 |
$542
6,465
kWh
|
$80
-
kW-mo/yr
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $637 | $1,519 |
$637
6,011
kWh
|
- | - | |
| 06 | 2.2437: Recover waste heat from equipment | $965 | $880 | - | - |
$965
-
MMBtu
|
|
| 07 | 2.7492: Use proper thickness of insulation on building envelope | $151 | $105 | - | - |
$151
-
MMBtu
|
|
| 08 | 2.6218: Turn off equipment when not in use | $1,319 | - |
$1,319
20,608
kWh
|
- | - | |
| 09 | 2.6218: Turn off equipment when not in use | $149 | $460 |
$149
2,327
kWh
|
- | - | |
| TOTAL RECOMMENDED | $14,393 | $21,347 |
$11,906
175,707
kWh
|
$1,199
-
kW-mo/yr
|
$1,288
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,958 | $20,362 |
$10,587
155,099
kWh
|
$1,199
-
kW-mo/yr
|
$172
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs