Assessment Year | 2013 |
---|---|
Principal Product | Plastic Extrusions |
NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 41 |
Plant Area |
90,000
ft2
|
Annual Production | 3,000,000
lb
|
Production Hrs. Annual | 6,500
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $131,315 | 2,168,000 |
kWh
|
$0.061 |
Electricity Demand | $47,566 | 5,596 |
kW-mo/yr
|
$8.50 |
Electricity Fees | $18,836 | - |
|
- |
Natural Gas | $12,910 | 1,800 |
MMBtu
|
$7.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $55,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,111 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2522: Isolate hot or cold equipment | $77 | $18 |
$77
1,260
kWh
|
- | - | - | |
02 | 2.2522: Isolate hot or cold equipment | $168 | $420 |
$168
2,741
kWh
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $310 | $135 |
$310
5,171
kWh
|
- | - | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $354 | $255 | - | - |
$354
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $656 | $3,892 |
$656
13,392
kWh
|
- | - | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,111 | - |
$1,086
17,753
kWh
|
$25
-
kW-mo/yr
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $1,566 | $1,034 |
$1,231
20,116
kWh
|
$335
-
kW-mo/yr
|
- | - | |
08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,581 | $1,410 | - | - |
$2,581
-
MMBtu
|
- | |
09 | 2.6218: Turn off equipment when not in use | $7,380 | $1,790 |
$7,380
120,002
kWh
|
- | - | - | |
10 | 3.4115: Recover and reuse cooling water | $41,508 | $45,500 | - | - | - |
$41,508
-
Tgal
|
|
TOTAL RECOMMENDED | $55,711 | $54,454 |
$10,908
180,435
kWh
|
$360
-
kW-mo/yr
|
$2,935
-
MMBtu
|
$41,508
-
Tgal
|
||
TOTAL IMPLEMENTED | $1,111 | - |
$1,086
17,753
kWh
|
$25
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs