Assessment Year | 2004 |
---|---|
Principal Product | Wooden doors |
NAICS | 321911: Wood Window and Door Manufacturing |
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
300,000
ft2
|
Annual Production | 150,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $258,061 | 7,675,600 |
kWh
|
$0.034 |
Electricity Demand | $205,968 | 20,174 |
kW-mo/yr
|
$10.21 |
Electricity Fees | $88,939 | - |
|
- |
Natural Gas | $175,771 | 24,113 |
MMBtu
|
$7.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,106 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,857 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $29,756 | $55,500 |
$29,756
842,943
kWh
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,773 | $50,985 |
$16,034
454,230
kWh
|
$9,739
-
kW-mo/yr
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $8,362 | $3,571 |
$4,835
136,960
kWh
|
$3,527
-
kW-mo/yr
|
- | - | |
04 | 4.443: Install automatic boiler fuel feed system | $6,615 | $13,500 | - | - | - | $6,615 | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,791 | $640 |
$1,069
30,289
kWh
|
$722
-
kW-mo/yr
|
- | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $1,495 | $500 | - | - |
$1,495
-
MMBtu
|
- | |
07 | 2.3132: Recharge batteries on during off-peak demand periods | $697 | $1,000 | - |
$697
-
kW-mo/yr
|
- | - | |
08 | 2.7134: Use photocell controls | $617 | $2,200 |
$617
17,465
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $75,106 | $127,896 |
$52,311
1,481,887
kWh
|
$14,685
-
kW-mo/yr
|
$1,495
-
MMBtu
|
$6,615 | ||
TOTAL IMPLEMENTED | $9,857 | $4,071 |
$4,835
136,960
kWh
|
$3,527
-
kW-mo/yr
|
$1,495
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs