ITAC Assessment: WI0482
ITAC logo
ITAC Assessment: WI0482
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Wooden doors
NAICS 321911: Wood Window and Door Manufacturing
SIC 2431: Millwork
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 300,000
ft2
Annual Production 150,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $258,061 7,675,600
kWh
Electricity Demand $205,968 20,174
kW-mo/yr
Electricity Fees $88,939 -
Natural Gas $175,771 24,113
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $75,106 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,857

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $29,756 $55,500 $29,756
842,943
kWh
- - -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $25,773 $50,985 $16,034
454,230
kWh
$9,739
-
kW-mo/yr
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $8,362 $3,571 $4,835
136,960
kWh
$3,527
-
kW-mo/yr
- -
04 4.443: Install automatic boiler fuel feed system $6,615 $13,500 - - - $6,615
05 2.4221: Install compressor air intakes in coolest locations $1,791 $640 $1,069
30,289
kWh
$722
-
kW-mo/yr
- -
06 2.6231: Utilize controls to operate equipment only when needed $1,495 $500 - - $1,495
-
MMBtu
-
07 2.3132: Recharge batteries on during off-peak demand periods $697 $1,000 - $697
-
kW-mo/yr
- -
08 2.7134: Use photocell controls $617 $2,200 $617
17,465
kWh
- - -
TOTAL RECOMMENDED $75,106 $127,896 $52,311
1,481,887
kWh
$14,685
-
kW-mo/yr
$1,495
-
MMBtu
$6,615
TOTAL IMPLEMENTED $9,857 $4,071 $4,835
136,960
kWh
$3,527
-
kW-mo/yr
$1,495
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs