Assessment Year | 2001 |
---|---|
Principal Product | X-Ray Diffraction Systems |
NAICS |
n/a
|
SIC | 3844: X-Ray Apparatus and Tubes and Related Irradiation Apparatus |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
45,600
ft2
|
Annual Production | 135
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $41,279 | 1,206,917 |
kWh
|
$0.034 |
Electricity Demand | $21,650 | 2,632 |
kW-mo/yr
|
$8.23 |
Electricity Fees | $4,425 | - |
|
- |
Natural Gas | $1,495 | 264 |
MMBtu
|
$5.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,562 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,658 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.6231: Utilize controls to operate equipment only when needed | $8,897 | - |
$8,897
247,948
kWh
|
- | - | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $6,828 | $9,500 |
$5,474
152,403
kWh
|
$1,354
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.8121: Apply for tax-free status for energy purchases | $2,958 | - | - | - | - | - | - | $2,958 | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $2,118 | $6,350 |
$1,698
47,186
kWh
|
$420
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $584 | $238 |
$483
13,482
kWh
|
$101
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $138 | - |
$112
3,224
kWh
|
$26
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.7224: Reduce space conditioning during non-working hours | $481 | - | - | - |
$481
-
MMBtu
|
- | - | - | |
08 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $397 | - | - | - | - |
$517
-
lb
|
$(-120.0) | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $161 | $640 |
$77
2,052
kWh
|
$84
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $22,562 | $16,728 |
$16,741
466,295
kWh
|
$1,985
-
kW-mo/yr
|
$481
-
MMBtu
|
$517
-
lb
|
$(-120.0) | $2,958 | ||
TOTAL IMPLEMENTED | $10,658 | $878 |
$9,569
266,706
kWh
|
$211
-
kW-mo/yr
|
$481
-
MMBtu
|
$517
-
lb
|
$(-120.0) | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs