Assessment Year 2000
Principal Product Commercial Newspaper
NAICS
n/a
SIC 2711: Newspapers: Publishing, or Publishing and Printing
Sales Range $10
M
to 50
M
# of Employees 425
Plant Area 120,000
ft2
Annual Production 27,196,000
pieces
Production Hrs. Annual 5,840
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $143,431 3,891,266
kWh
Electricity Demand $91,060 7,406
kW-mo/yr
Electricity Fees $15,320 -
Natural Gas $32,989 12,263
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $27,198 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,952

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 3.6193: Install equipment (eg compactor) to reduce disposal costs $5,774 - - - $5,774
-
lb
-
02 2.6231: Utilize controls to operate equipment only when needed $5,393 - $4,018
102,872
kWh
$1,375
-
kW-mo/yr
- -
03 3.7137: Replace cloth rags with paper towels $5,263 - - - - $5,263
04 2.6218: Turn off equipment when not in use $4,608 - $2,775
71,219
kWh
$1,833
-
kW-mo/yr
- -
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $544 - $280
7,327
kWh
$264
-
kW-mo/yr
- -
06 2.7142: Utilize higher efficiency lamps and/or ballasts $2,983 $12,478 $1,686
43,083
kWh
$1,297
-
kW-mo/yr
- -
07 2.4221: Install compressor air intakes in coolest locations $1,576 $1,280 $723
18,464
kWh
$853
-
kW-mo/yr
- -
08 2.3132: Recharge batteries on during off-peak demand periods $1,057 $100 - $1,057
-
kW-mo/yr
- -
TOTAL RECOMMENDED $27,198 $13,858 $9,482
242,965
kWh
$6,679
-
kW-mo/yr
$5,774
-
lb
$5,263
TOTAL IMPLEMENTED $18,952 $1,380 $7,796
199,882
kWh
$5,382
-
kW-mo/yr
$5,774
-
lb
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs