| Assessment Year | 1998 |
|---|---|
| Principal Product | Newpapers |
| NAICS |
n/a
|
| SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
| Sales Range | $5 M to 10M |
| # of Employees | 250 |
| Plant Area |
45,000
ft2
|
| Annual Production | 12,775,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $54,555 | 1,432,591 |
kWh
|
$0.038 |
| Electricity Demand | $33,334 | 2,693 |
kW-mo/yr
|
$12.38 |
| Electricity Fees | $5,243 | - |
|
- |
| Natural Gas | $9,815 | 2,011 |
MMBtu
|
$4.88 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,464 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,101 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 4.321: Optimize production lot sizes and inventories | $13,100 | - | - | - | - | - | $13,100 | |
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $7,343 | - |
$5,495
137,456
kWh
|
$1,848
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.7135: Install occupancy sensors | $4,466 | $7,200 |
$3,091
77,374
kWh
|
$1,375
-
kW-mo/yr
|
- | - | - | |
| 04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,266 | $9,500 | - | - | - |
$3,266
-
lb
|
- | |
| 05 | 3.6192: Use a less expensive method of waste removal | $528 | $800 | - | - | - |
$528
-
lb
|
- | |
| 06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,573 | $590 | - | - |
$1,573
-
MMBtu
|
- | - | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $701 | - |
$526
13,189
kWh
|
$175
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.7122: Disconnect ballasts | $487 | - |
$112
2,931
kWh
|
$375
-
kW-mo/yr
|
- | - | - | |
| TOTAL RECOMMENDED | $31,464 | $18,090 |
$9,224
230,950
kWh
|
$3,773
-
kW-mo/yr
|
$1,573
-
MMBtu
|
$3,794
-
lb
|
$13,100 | ||
| TOTAL IMPLEMENTED | $2,101 | $1,390 | - | - |
$1,573
-
MMBtu
|
$528
-
lb
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs