Assessment Year 1998
Principal Product Washroom Accessories
NAICS
n/a
SIC 3432: Plumbing Fixture Fittings and Trim
Sales Range $10
M
to 50
M
# of Employees 112
Plant Area 120,879
ft2
Annual Production 482,500
pieces
Production Hrs. Annual 4,250
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $42,662 1,328,546
kWh
Electricity Demand $30,453 3,590
kW-mo/yr
Electricity Fees $720 -
Natural Gas $36,609 6,578
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $55,421 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 4.111: Add equipment/ operators to reduce production bottleneck $21,516 $1,000 - - - - $21,516 -
02 2.8113: Purchase gas directly from a contract gas supplier $11,052 $500 - - $11,052
-
MMBtu
- - -
03 2.7261: Install timers and/or thermostats $6,348 $1,000 - - $6,348
-
MMBtu
- - -
04 2.7243: Improve air circulation with destratification fans / other methods $4,205 $4,500 $(-262.0)
(-7,620)
kWh
- $4,467
-
MMBtu
- - -
05 3.5315: Lease / purchase baler; sell cardboard to recycler $4,677 $9,000 $(-23.0)
(-586)
kWh
- - $4,700
-
lb
- -
06 2.3134: Shift from daytime to nighttime operation $3,817 - - $6,048
-
kW-mo/yr
- - $(-2,231.0) -
07 2.3132: Recharge batteries on during off-peak demand periods $1,087 $600 - $1,087
-
kW-mo/yr
- - - -
08 4.321: Optimize production lot sizes and inventories $2,376 - - - - - - $2,376
09 2.4221: Install compressor air intakes in coolest locations $343 $740 $171
4,982
kWh
$172
-
kW-mo/yr
- - - -
TOTAL RECOMMENDED $55,421 $17,340 $(-114.0)
(-3,224)
kWh
$7,307
-
kW-mo/yr
$21,867
-
MMBtu
$4,700
-
lb
$19,285 $2,376
TOTAL IMPLEMENTED - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs