Assessment Year 1996
Principal Product Corrugated containers
NAICS
n/a
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area 170,000
ft2
Annual Production 480,000
thousand feet
Production Hrs. Annual 4,250
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $171,903 3,779,308
kWh
Electricity Demand $123,953 10,238
kW-mo/yr
Electricity Fees $(-3,976.0) -
Natural Gas $114,772 38,400
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $44,670 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $5,818

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
01 2.2426: Use waste heat from flue gases to heat space conditioning air $18,642 $10,000 $(-221.0)
(-4,689)
kWh
- $18,863
-
MMBtu
-
02 2.7261: Install timers and/or thermostats $6,122 $1,600 - - $6,122
-
MMBtu
-
03 3.6193: Install equipment (eg compactor) to reduce disposal costs $5,800 - - - - $5,800
-
lb
04 2.7243: Improve air circulation with destratification fans / other methods $4,365 $9,500 $652
(-13,775)
kWh
- $3,713
-
MMBtu
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,538 $1,642 $1,384
29,015
kWh
$1,154
-
kW-mo/yr
- -
06 2.4221: Install compressor air intakes in coolest locations $2,245 $640 $1,376
28,722
kWh
$869
-
kW-mo/yr
- -
07 2.1123: Install automatic stack damper $1,948 $3,000 - - $1,948
-
MMBtu
-
08 2.1233: Analyze flue gas for proper air/fuel ratio $1,453 $500 - - $1,453
-
MMBtu
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $1,309 $1,849 $729
15,240
kWh
$580
-
kW-mo/yr
- -
10 2.7241: Install outside air damper / economizer on hvac unit $248 $700 $248
5,275
kWh
- - -
TOTAL RECOMMENDED $44,670 $29,431 $4,168
59,788
kWh
$2,603
-
kW-mo/yr
$32,099
-
MMBtu
$5,800
-
lb
TOTAL IMPLEMENTED $5,818 $10,000 $652
(-13,775)
kWh
- $5,166
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs