Assessment Year | 2010 |
---|---|
Principal Product | Automobile structural parts |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
314,000
ft2
|
Annual Production | 20,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $160,631 | 4,867,600 |
kWh
|
$0.033 |
Electricity Demand | $243,399 | 17,898 |
kW-mo/yr
|
$13.60 |
Electricity Fees | $42,472 | - |
|
- |
Natural Gas | $133,857 | 15,255 |
MMBtu
|
$8.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,039 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,404 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $9,404 | $12,450 |
$4,438
134,496
kWh
|
$4,966
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,696 | $100 |
$2,846
86,234
kWh
|
$2,850
-
kW-mo/yr
|
- | - | |
03 | 2.7134: Use photocell controls | $1,578 | $835 |
$416
12,591
kWh
|
$602
-
kW-mo/yr
|
$133 | $427 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $361 | $425 |
$165
4,993
kWh
|
$93
-
kW-mo/yr
|
$43 | $60 | |
TOTAL RECOMMENDED | $17,039 | $13,810 |
$7,865
238,314
kWh
|
$8,511
-
kW-mo/yr
|
$176 | $487 | ||
TOTAL IMPLEMENTED | $9,404 | $12,450 |
$4,438
134,496
kWh
|
$4,966
-
kW-mo/yr
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs