Assessment Year | 1996 |
---|---|
Principal Product | Forgings (tractor/off road) |
NAICS |
n/a
|
SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
175,000
ft2
|
Annual Production | 500
pieces
|
Production Hrs. Annual | 3,760
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $73,737 | 2,820,926 |
kWh
|
$0.026 |
Electricity Demand | $85,652 | 11,487 |
kW-mo/yr
|
$7.46 |
Electricity Fees | $(-2,579.0) | - |
|
- |
Natural Gas | $536,714 | 220,801 |
MMBtu
|
$2.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $19,840 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,780 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1242: Minimize boiler blowdown with better feedwater treatment | $6,680 | $2,500 | - | - |
$2,790
-
MMBtu
|
$2,280 |
$1,610
-
Tgal
|
|
02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,481 | $30,000 |
$8,646
315,651
kWh
|
$6,572
-
kW-mo/yr
|
$(-8,737.0)
-
MMBtu
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $1,572 | $1,280 |
$848
31,067
kWh
|
$724
-
kW-mo/yr
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $899 | $600 | - | - |
$899
-
MMBtu
|
- | - | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,072 | $1,800 | - | - |
$2,072
-
MMBtu
|
- | - | |
06 | 2.7447: Install vinyl strip / high speed / air curtain doors | $150 | $250 | - | - |
$150
-
MMBtu
|
- | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,546 | $1,220 |
$696
25,498
kWh
|
$850
-
kW-mo/yr
|
- | - | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $440 | - |
$197
7,327
kWh
|
$243
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $19,840 | $37,650 |
$10,387
379,543
kWh
|
$8,389
-
kW-mo/yr
|
$(-2,826.0)
-
MMBtu
|
$2,280 |
$1,610
-
Tgal
|
||
TOTAL IMPLEMENTED | $5,780 | $4,550 |
$1,741
63,892
kWh
|
$1,817
-
kW-mo/yr
|
$2,222
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs