| Assessment Year | 1996 |
|---|---|
| Principal Product | Stainless Vessels Product |
| NAICS |
n/a
|
| SIC | 3441: Fabricated Structural Metal |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
80,000
ft2
|
| Annual Production | 12,000
pieces
|
| Production Hrs. Annual | 2,190
hrs
|
| Location (State) | Wisconsin |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $118,056 | 2,035,463 |
kWh
|
$0.058 |
| Electricity Demand | $58,858 | 8,016 |
kW-mo/yr
|
$7.34 |
| Electricity Fees | $4,058 | - |
|
- |
| Natural Gas | $49,262 | 11,199 |
MMBtu
|
$4.40 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,376 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,063 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $9,926 | $4,400 | - | - | - |
$9,926
-
MMBtu
|
- | |
| 02 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $9,406 | $50,000 |
$8,882
326,788
kWh
|
$10,353
-
kW-mo/yr
|
- |
$(-9,829.0)
-
MMBtu
|
- | |
| 03 | 2.8121: Apply for tax-free status for energy purchases | $7,447 | - | - | - | $7,447 | - | - | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,690 | $1,600 | - | - | - |
$1,690
-
MMBtu
|
- | |
| 05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $4,800 | - | - | - | - | - |
$4,800
-
lb
|
|
| 06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,107 | $500 | - | - | - |
$1,107
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $34,376 | $56,500 |
$8,882
326,788
kWh
|
$10,353
-
kW-mo/yr
|
$7,447 |
$2,894
-
MMBtu
|
$4,800
-
lb
|
||
| TOTAL IMPLEMENTED | $19,063 | $6,000 | - | - | $7,447 |
$11,616
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs