| Assessment Year | 1995 |
|---|---|
| Principal Product | Fruit Juices |
| NAICS |
n/a
|
| SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
| Sales Range | $50 M to 100M |
| # of Employees | 110 |
| Plant Area |
200,000
ft2
|
| Annual Production | 150,000,000
lb
|
| Production Hrs. Annual | 4,375
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $338,315 | 5,001,172 |
kWh
|
$0.068 |
| Natural Gas | $17,221 | 4,188 |
MMBtu
|
$4.11 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $17,718 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,090 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3132: Recharge batteries on during off-peak demand periods | $3,378 | $12,000 |
$3,378
-
kWh
|
- | |
| 02 | 2.2437: Recover waste heat from equipment | $4,034 | $2,000 | - |
$4,034
-
MMBtu
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $2,406 | $1,600 |
$2,406
35,463
kWh
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,533 | $2,043 |
$1,533
22,567
kWh
|
- | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $288 | - |
$288
4,396
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,059 | $1,581 |
$1,059
15,533
kWh
|
- | |
| 07 | 2.2621: Modify refrigeration system to operate at a lower pressure | $3,406 | $10,000 |
$3,406
50,410
kWh
|
- | |
| 08 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,210 | $5,800 | - |
$1,210
-
MMBtu
|
|
| 09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $404 | $500 | - |
$404
-
MMBtu
|
|
| TOTAL RECOMMENDED | $17,718 | $35,524 |
$12,070
128,369
kWh
|
$5,648
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $4,090 | $9,424 |
$2,880
42,496
kWh
|
$1,210
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs