Assessment Year 2025
Principal Product Electronic Components
NAICS 334419: Other Electronic Component Manufacturing
SIC 3679: Electronic Components, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 148
Plant Area 85,000
ft2
Annual Production 15,000
units
Production Hrs. Annual 2,356
hrs
Location (State) Arizona

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,270 2,453,760
kWh
Electricity Demand $39,976 4,584
kW-mo/yr
Electricity Fees $31,259 -
TOTAL YEARLY COSTS $262,505
RECOMMENDED SAVINGS* $25,808 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.2628: Utilize a less expensive cooling method $14,690 $25,500 $14,690
188,575
kWh
- - -
02 2.3212: Optimize plant power factor $6,580 $17,986 - - $6,580 -
03 2.7243: Improve air circulation with destratification fans / other methods $2,531 $210 $(-61.0)
(-788)
kWh
- - $2,592
04 2.7261: Install timers and/or thermostats $929 $2,002 $929
11,936
kWh
- - -
05 2.6218: Turn off equipment when not in use $583 $2,577 $583
7,488
kWh
- - -
06 2.6211: Conserve energy by efficient use of vending machines $431 $818 $359
4,612
kWh
$72
-
kW-mo/yr
- -
07 2.6242: Minimize operation of equipment maintained in standby condition $64 $260 $64
817
kWh
- - -
TOTAL RECOMMENDED $25,808 $49,353 $16,564
212,640
kWh
$72
-
kW-mo/yr
$6,580 $2,592
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs