Assessment Year | 1995 |
---|---|
Principal Product | Semi finished ice cream, yogurt, whipped cream, and non-dair |
NAICS |
n/a
|
SIC | 2023: Dry, Condensed, and Evaporated Dairy Products |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
40,000
ft2
|
Annual Production | 8,000
Tgal
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $164,211 | 2,248,242 |
kWh
|
$0.073 |
Natural Gas | $61,757 | 12,978 |
MMBtu
|
$4.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $14,499 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,507 | $500 | - |
$3,507
-
MMBtu
|
|
02 | 2.2414: Use waste heat from hot flue gases to preheat | $2,343 | $10,000 | - |
$2,343
-
MMBtu
|
|
03 | 2.7221: Lower temperature during the winter season and vice-versa | $3,427 | $20 | - |
$3,427
-
MMBtu
|
|
04 | 2.7221: Lower temperature during the winter season and vice-versa | $1,004 | - | - |
$1,004
-
MMBtu
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,246 | $1,805 |
$3,246
44,549
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $188 | - |
$188
2,638
kWh
|
- | |
07 | 2.7444: Close holes and openings in building such as broken windows | $401 | $260 | - |
$401
-
MMBtu
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $244 | $640 |
$244
3,224
kWh
|
- | |
09 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $139 | - |
$139
-
kWh
|
- | |
TOTAL RECOMMENDED | $14,499 | $13,225 |
$3,817
50,411
kWh
|
$10,682
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs