| Assessment Year | 1995 |
|---|---|
| Principal Product | Polyurethane film and bags used for packaging |
| NAICS |
n/a
|
| SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
| Sales Range | $10 M to 50M |
| # of Employees | 50 |
| Plant Area |
50,000
ft2
|
| Annual Production | 13,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $246,717 | 5,093,787 |
kWh
|
$0.048 |
| Natural Gas | $11,938 | 1,949 |
MMBtu
|
$6.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,549 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $879 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7263: Lower compressor pressure through a/c system modification | $16,786 | $30,000 |
$16,786
346,424
kWh
|
- | - | |
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $1,721 | $200 | - |
$1,721
-
MMBtu
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,205 | $1,383 |
$1,205
24,912
kWh
|
- | - | |
| 04 | 2.7241: Install outside air damper / economizer on hvac unit | $1,065 | $1,400 |
$1,065
21,981
kWh
|
- | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $638 | $576 |
$638
13,189
kWh
|
- | - | |
| 06 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $520 | - | - | - | $520 | |
| 07 | 2.2511: Insulate bare equipment | $245 | $100 |
$245
4,982
kWh
|
- | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $241 | $960 |
$241
4,982
kWh
|
- | - | |
| 09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $128 | - |
$128
2,638
kWh
|
- | - | |
| TOTAL RECOMMENDED | $22,549 | $34,619 |
$20,308
419,108
kWh
|
$1,721
-
MMBtu
|
$520 | ||
| TOTAL IMPLEMENTED | $879 | $1,536 |
$879
18,171
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs