ITAC Assessment: WI0214
ITAC logo
ITAC Assessment: WI0214
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Reflectors for lighting fixtures (indoor and outdoor)
NAICS
n/a
SIC 3648: Lighting Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 200
Plant Area 100,000
ft2
Annual Production 73,500,000
pieces
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $396,395 5,690,504
kWh
Natural Gas $191,821 56,567
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $71,503 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $18,761

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings
01 2.3132: Recharge batteries on during off-peak demand periods $30,762 $31,200 $30,762
-
kWh
- -
02 2.2621: Modify refrigeration system to operate at a lower pressure $10,026 $15,000 $10,026
143,904
kWh
- -
03 2.7224: Reduce space conditioning during non-working hours $9,933 $600 - $9,933
-
MMBtu
-
04 2.7447: Install vinyl strip / high speed / air curtain doors $3,450 $350 - $3,450
-
MMBtu
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,054 $2,036 $2,054
29,601
kWh
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $323 - $323
4,689
kWh
- -
07 2.1233: Analyze flue gas for proper air/fuel ratio $1,682 $500 - $1,682
-
MMBtu
-
08 2.2437: Recover waste heat from equipment $1,097 $1,600 - $1,097
-
MMBtu
-
09 2.4221: Install compressor air intakes in coolest locations $1,642 $640 $1,642
23,447
kWh
- -
10 2.7241: Install outside air damper / economizer on hvac unit $384 $700 $384
5,569
kWh
- -
11 3.1161: Eliminate/reduce an operation $7,500 - - - $7,500
-
lb
12 3.1191: Change procedures / equipment / operating conditions $2,650 $2,500 - - $2,650
-
lb
TOTAL RECOMMENDED $71,503 $55,126 $45,191
207,210
kWh
$16,162
-
MMBtu
$10,150
-
lb
TOTAL IMPLEMENTED $18,761 $4,126 $3,696
53,048
kWh
$15,065
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Solid Waste (non-haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs