Assessment Year 1994
Principal Product chillers, condensers, heat exchangers
NAICS
n/a
SIC 3443: Fabricated Plate Work (Boiler Shops)
Sales Range $10
M
to 50
M
# of Employees 125
Plant Area 160,000
ft2
Annual Production 30,000
pieces
Production Hrs. Annual 4,125
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $197,501 1,794,256
kWh
Natural Gas $60,231 22,584
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $38,483 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $10,761

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2612: Use cooling tower water instead of refrigeration $10,895 $20,000 $10,895
-
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $10,761 $8,956 $10,761
97,890
kWh
-
03 2.7135: Install occupancy sensors $290 $150 $290
2,638
kWh
-
04 2.7134: Use photocell controls $116 $75 $116
1,172
kWh
-
05 2.7447: Install vinyl strip / high speed / air curtain doors $8,734 $21,885 - $8,734
-
MMBtu
06 2.2511: Insulate bare equipment $258 $912 - $258
-
MMBtu
07 2.4221: Install compressor air intakes in coolest locations $3,426 $2,920 $3,426
31,067
kWh
-
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $3,316 $2,257 $3,316
30,188
kWh
-
09 2.4111: Utilize energy-efficient belts and other improved mechanisms $687 - $687
6,155
kWh
-
TOTAL RECOMMENDED $38,483 $57,155 $29,491
169,110
kWh
$8,992
-
MMBtu
TOTAL IMPLEMENTED $10,761 $8,956 $10,761
97,890
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs