Assessment Year | 1995 |
---|---|
Principal Product | Steel Casting,Valves,Oil Industri Tools,Crane & Cable Parts |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 250 |
Plant Area |
197,500
ft2
|
Annual Production | 4,000
ton
|
Production Hrs. Annual | 2,750
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $897,772 | 15,792,790 |
kWh
|
$0.057 |
Natural Gas | $243,859 | 97,656 |
MMBtu
|
$2.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,655 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1113: Reduce combustion air flow to optimum | $26,990 | $5,000 | - |
$26,990
-
MMBtu
|
|
02 | 2.1113: Reduce combustion air flow to optimum | $10,625 | $2,500 | - |
$10,625
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $4,597 | $17,060 |
$4,597
90,563
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,788 | $767 |
$1,788
33,705
kWh
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,330 | $2,480 |
$1,330
34,877
kWh
|
- | |
06 | 2.4314: Use synthetic lubricant | $325 | - |
$325
24,912
kWh
|
- | |
TOTAL RECOMMENDED | $45,655 | $27,807 |
$8,040
184,057
kWh
|
$37,615
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs