Assessment Year | 1993 |
---|---|
Principal Product | Roofing Product |
NAICS |
n/a
|
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
35,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,500
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,455 | 182,884 |
kWh
|
$0.13 |
Natural Gas | $14,932 | 3,280 |
MMBtu
|
$4.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,260 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,773 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,239 | $2,000 | - |
$3,239
-
MMBtu
|
|
02 | 2.7224: Reduce space conditioning during non-working hours | $1,978 | $600 | - |
$1,978
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,228 | $1,399 |
$1,228
9,672
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $665 | $225 |
$665
5,275
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $594 | - |
$594
4,689
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $556 | $1,600 |
$556
4,396
kWh
|
- | |
TOTAL RECOMMENDED | $8,260 | $5,824 |
$3,043
24,032
kWh
|
$5,217
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,773 | $4,200 |
$556
4,396
kWh
|
$5,217
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs