Assessment Year | 1993 |
---|---|
Principal Product | Speciality coatings |
NAICS |
n/a
|
SIC | 2851: Paints, Varnishes, Lacquers, Enamels, and Allied Products |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
140,000
ft2
|
Annual Production | 2,350
Tgal
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $486,662 | 6,623,388 |
kWh
|
$0.073 |
Natural Gas | $155,607 | 50,656 |
MMBtu
|
$3.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,833 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,298 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7224: Reduce space conditioning during non-working hours | $14,279 | $1,000 | - |
$14,279
-
MMBtu
|
|
02 | 2.3132: Recharge batteries on during off-peak demand periods | $9,577 | - |
$9,577
-
kWh
|
- | |
03 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $6,797 | $35,000 |
$8,271
112,544
kWh
|
$(-1,474.0)
-
MMBtu
|
|
04 | 2.7241: Install outside air damper / economizer on hvac unit | $4,379 | $6,300 |
$4,379
59,496
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,804 | - |
$3,804
51,876
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,917 | $8,021 |
$2,917
39,566
kWh
|
- | |
07 | 2.2428: Use flue gases in radiant heater for space heating, ovens, etc | $1,633 | $1,000 | - |
$1,633
-
MMBtu
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $1,000 | $960 |
$1,000
13,775
kWh
|
- | |
09 | 2.7447: Install vinyl strip / high speed / air curtain doors | $447 | $1,056 | - |
$447
-
MMBtu
|
|
TOTAL RECOMMENDED | $44,833 | $53,337 |
$29,948
277,257
kWh
|
$14,885
-
MMBtu
|
||
TOTAL IMPLEMENTED | $16,298 | $8,021 |
$16,298
91,442
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs