Assessment Year 1991
Principal Product AUDIO EQUIPMENT
NAICS
n/a
SIC 3699: Electrical Machinery, Equipment, and Supplies, Not Elsewhere
Sales Range $10
M
to 50
M
# of Employees 240
Plant Area
n/a
Annual Production 10,000,000
pieces
Production Hrs. Annual 2,125
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $161,724 1,707,210
kWh
Natural Gas $55,196 16,196
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,784 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,784

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.7261: Install timers and/or thermostats $13,347 $6,250 - $13,347
-
MMBtu
02 2.7221: Lower temperature during the winter season and vice-versa $6,683 - - $6,683
-
MMBtu
03 2.7221: Lower temperature during the winter season and vice-versa $3,030 - $3,030
31,946
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $4,688 $16,237 $4,688
49,531
kWh
-
05 2.1233: Analyze flue gas for proper air/fuel ratio $1,530 $500 - $1,530
-
MMBtu
06 2.2437: Recover waste heat from equipment $716 $800 - $716
-
MMBtu
07 2.7494: Install storm windows and doors $803 $2,466 - $803
-
MMBtu
08 2.4221: Install compressor air intakes in coolest locations $508 $700 $508
5,275
kWh
-
09 2.6222: Use drying oven (batch type) on alternate days or other optimum schedule to run equipment with full loads $1,254 - $1,254
13,189
kWh
-
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $225 - $225
2,345
kWh
-
TOTAL RECOMMENDED $32,784 $26,953 $9,705
102,286
kWh
$23,079
-
MMBtu
TOTAL IMPLEMENTED $32,784 $26,953 $9,705
102,286
kWh
$23,079
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs