Assessment Year 1991
Principal Product AUTO LIGHTING LENSES
NAICS
n/a
SIC 3647: Vehicular Lighting Equipment
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 6,000
hrs
Location (State) Illinois

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $630,024 9,152,697
kWh
Natural Gas $148,658 33,197
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $55,680 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2511: Insulate bare equipment $32,440 $10,800 $32,440
471,278
kWh
-
02 2.3191: Use demand controller or load shedder $11,780 $10,000 $11,780
-
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,727 $3,515 $2,727
39,566
kWh
-
04 2.2437: Recover waste heat from equipment $1,862 $800 - $1,862
-
MMBtu
05 2.6232: Install set-back timers $1,351 $600 $1,351
19,637
kWh
-
06 2.1233: Analyze flue gas for proper air/fuel ratio $1,015 $500 - $1,015
-
MMBtu
07 2.6212: Turn off equipment during breaks, reduce operating time $958 $1,000 $958
14,068
kWh
-
08 2.4221: Install compressor air intakes in coolest locations $912 $1,500 $912
13,189
kWh
-
09 2.7494: Install storm windows and doors $733 $1,544 - $733
-
MMBtu
10 2.4111: Utilize energy-efficient belts and other improved mechanisms $383 - $383
5,569
kWh
-
11 2.6121: Reduce hot water temperature to the minimum required $299 - $299
4,396
kWh
-
12 2.7221: Lower temperature during the winter season and vice-versa $1,220 - - $1,220
-
MMBtu
TOTAL RECOMMENDED $55,680 $30,259 $50,850
567,703
kWh
$4,830
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs