Assessment Year | 1990 |
---|---|
Principal Product | WALL BOARD - GYPSUM |
NAICS |
n/a
|
SIC | 3275: Gypsum Products |
Sales Range | $10 M to 50M |
# of Employees | 78 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $767,857 | 12,096,718 |
kWh
|
$0.063 |
Natural Gas | $1,648,369 | 598,244 |
MMBtu
|
$2.76 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,027 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,656 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.3134: Shift from daytime to nighttime operation | $25,487 | - |
$29,087
-
kWh
|
$(-3,600.0) | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,611 | $1,764 |
$2,611
41,032
kWh
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,656 | - |
$1,656
26,084
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $788 | $2,000 |
$788
12,309
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $257 | $97 |
$257
3,810
kWh
|
- | |
06 | 2.6232: Install set-back timers | $228 | $200 |
$228
3,517
kWh
|
- | |
TOTAL RECOMMENDED | $31,027 | $4,061 |
$34,627
86,752
kWh
|
$(-3,600.0) | ||
TOTAL IMPLEMENTED | $3,656 | $3,861 |
$3,656
57,151
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |