Assessment Year 1989
Principal Product TANNED LEATHER
NAICS
n/a
SIC 3111: Leather Tanning and Finishing
Sales Range $5
M
to 10
M
# of Employees 65
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 3,000
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $76,473 907,972
kWh
Natural Gas $65,394 14,626
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,407 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.8113: Purchase gas directly from a contract gas supplier $20,276 - - $20,276
-
MMBtu
02 2.4312: Improve lubrication practices $4,500 - $4,500
53,341
kWh
-
03 2.4133: Use most efficient type of electric motors $4,092 $3,750 $4,092
48,652
kWh
-
04 2.2414: Use waste heat from hot flue gases to preheat $1,448 $5,000 - $1,448
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $996 $258 $996
11,723
kWh
-
06 2.7447: Install vinyl strip / high speed / air curtain doors $1,280 $1,900 - $1,280
-
MMBtu
07 2.7494: Install storm windows and doors $532 $1,358 - $532
-
MMBtu
08 2.4221: Install compressor air intakes in coolest locations $283 $1,000 $283
3,224
kWh
-
TOTAL RECOMMENDED $33,407 $13,266 $9,871
116,940
kWh
$23,536
-
MMBtu
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs