Assessment Year | 1989 |
---|---|
Principal Product | FOLDING CARTONS |
NAICS |
n/a
|
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
n/a
|
Annual Production | 1,800
ton
|
Production Hrs. Annual | 4,750
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $90,068 | 1,091,149 |
kWh
|
$0.083 |
Natural Gas | $10,028 | 2,642 |
MMBtu
|
$3.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,658 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,536 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $3,236 | - |
$3,636
-
kWh
|
- | $(-400.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $564 | $3,238 |
$564
6,741
kWh
|
- | - | |
03 | 2.4312: Improve lubrication practices | $1,866 | - |
$1,866
22,567
kWh
|
- | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,052 | $1,000 | - |
$1,052
-
MMBtu
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $328 | $700 |
$407
4,982
kWh
|
$(-79.0)
-
MMBtu
|
- | |
06 | 2.7261: Install timers and/or thermostats | $301 | $250 | - |
$301
-
MMBtu
|
- | |
07 | 2.7446: Utilize sensors controlling roof and wall openings | $283 | $400 |
$283
3,517
kWh
|
- | - | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $165 | - |
$165
2,052
kWh
|
- | - | |
09 | 2.6214: Shut off pilots in standby equipment | $133 | - | - |
$133
-
MMBtu
|
- | |
10 | 2.6121: Reduce hot water temperature to the minimum required | $730 | - |
$730
9,086
kWh
|
- | - | |
TOTAL RECOMMENDED | $8,658 | $5,588 |
$7,651
48,945
kWh
|
$1,407
-
MMBtu
|
$(-400.0) | ||
TOTAL IMPLEMENTED | $5,536 | $250 |
$5,502
22,567
kWh
|
$434
-
MMBtu
|
$(-400.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs