| Assessment Year | 2024 |
|---|---|
| Principal Product | Contracted powder coating services for metal parts mainly electrical equipment |
| NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
| SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
73,750
ft2
|
| Annual Production | 2,493
units
|
| Production Hrs. Annual | 2,493
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $84,410 | 1,070,372 |
kWh
|
$0.079 |
| Electricity Demand | $38,725 | 6,206 |
kW-mo/yr
|
$6.24 |
| Electricity Fees | $26,199 | - |
|
- |
| Natural Gas | $172,257 | 42,168 |
MMBtu
|
$4.09 |
| TOTAL YEARLY COSTS | $321,591 | |||
| RECOMMENDED SAVINGS* | $52,736 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $19,703 | $150,942 |
$17,259
218,851
kWh
|
$2,444
-
kW-mo/yr
|
- | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,783 | $12,225 |
$9,783
124,055
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,528 | $1,620 |
$5,528
69,980
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,612 | $8,564 |
$5,080
55,827
kWh
|
$1,532
-
kW-mo/yr
|
- | |
| 05 | 2.7135: Install occupancy sensors | $2,583 | $1,264 |
$2,583
32,691
kWh
|
- | - | |
| 06 | 2.2437: Recover waste heat from equipment | $8,527 | $31,200 | - | - |
$8,527
-
MMBtu
|
|
| TOTAL RECOMMENDED | $52,736 | $205,815 |
$40,233
501,404
kWh
|
$3,976
-
kW-mo/yr
|
$8,527
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs