Assessment Year | 1989 |
---|---|
Principal Product | SOFT DRINKS |
NAICS |
n/a
|
SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
Sales Range | $1 M to 5M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 4,500,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Wisconsin |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $127,117 | 2,303,048 |
kWh
|
$0.055 |
Natural Gas | $115,465 | 23,657 |
MMBtu
|
$4.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $68,489 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $891 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $1,153 | $5,000 |
$1,153
20,809
kWh
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $891 | $1,500 |
$891
16,120
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,621 | $4,032 |
$1,621
29,308
kWh
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $26,352 | $8,400 | - |
$26,352
-
MMBtu
|
- | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,295 | $500 | - |
$1,345
-
MMBtu
|
$(-50.0) | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $119 | - | - |
$169
-
MMBtu
|
$(-50.0) | |
07 | 2.6124: Establish equipment maintenance schedule | $1,251 | - | - |
$1,351
-
MMBtu
|
$(-100.0) | |
08 | 2.8113: Purchase gas directly from a contract gas supplier | $35,807 | - | - |
$35,807
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $68,489 | $19,432 |
$3,665
66,237
kWh
|
$65,024
-
MMBtu
|
$(-200.0) | ||
TOTAL IMPLEMENTED | $891 | $1,500 |
$891
16,120
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs