ITAC Assessment: WI0001
ITAC logo
ITAC Assessment: WI0001
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product PACKAGING MACHINERY
NAICS
n/a
SIC 3556: Food Products Machinery
Sales Range $5
M
to 10
M
# of Employees 40
Plant Area
n/a
Annual Production 0
units
Production Hrs. Annual 2,405
hrs
Location (State) Wisconsin

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $15,455 204,865
kWh
Natural Gas $6,723 1,126
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $4,211 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,385

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4312: Improve lubrication practices $1,304 - $1,304
17,292
kWh
-
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $332 - $332
4,396
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,150 $216 $1,150
15,240
kWh
-
04 2.4221: Install compressor air intakes in coolest locations $265 $148 $265
3,517
kWh
-
05 2.1311: Replace electrically-operated equipment with fossil fuel equipment $342 $350 $509
6,741
kWh
$(-167.0)
-
MMBtu
06 2.1233: Analyze flue gas for proper air/fuel ratio $334 $400 - $334
-
MMBtu
07 2.7447: Install vinyl strip / high speed / air curtain doors $484 $800 - $484
-
MMBtu
TOTAL RECOMMENDED $4,211 $1,914 $3,560
47,186
kWh
$651
-
MMBtu
TOTAL IMPLEMENTED $3,385 $764 $3,051
40,445
kWh
$334
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs