Assessment Year 2025
Principal Product Structural Steel Fabrication
NAICS 332312: Fabricated Structural Metal Manufacturing
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 124
Plant Area 187,600
ft2
Annual Production 11,712
ton
Production Hrs. Annual 6,048
hrs
Location (State) Washington

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $181,705 1,739,600
kWh
Electricity Demand $32,218 5,781
kW-mo/yr
Electricity Fees $26,998 -
Natural Gas $60,273 5,917
MMBtu
Fuel Oil #1 $26,272 921
MMBtu
TOTAL YEARLY COSTS $327,466
RECOMMENDED SAVINGS* $257,405 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Fuel Oil #1 Savings
01 2.4221: Install compressor air intakes in coolest locations $24,319 $2,741 $24,226
242,261
kWh
$93
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $24,637 $15,000 $22,254
212,958
kWh
$2,383
-
kW-mo/yr
- -
03 2.9114: Use solar heat to make electricty $60,995 $262,084 $55,177
528,014
kWh
$5,818
-
kW-mo/yr
- -
04 2.7447: Install vinyl strip / high speed / air curtain doors $16,531 $210,600 - - $16,531
-
MMBtu
-
05 2.4322: Use or replace with energy efficient substitutes $88,305 $146,250 - - - $88,305
-
MMBtu
06 2.7491: Insulate glazing, walls, ceilings, and roofs $9,630 $149,864 - - - $9,630
-
MMBtu
07 2.4321: Upgrade obsolete equipment $32,988 $55,500 $32,700
312,984
kWh
$288
-
kW-mo/yr
- -
TOTAL RECOMMENDED $257,405 $842,039 $134,357
1,296,217
kWh
$8,582
-
kW-mo/yr
$16,531
-
MMBtu
$97,935
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Fuel Oil #1 Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs