| Assessment Year | 2013 |
|---|---|
| Principal Product | Paperboard cartons |
| NAICS | 322212: Folding Paperboard Box Manufacturing |
| SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
102,000
ft2
|
| Annual Production | 250,000,000
pieces
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $153,551 | 3,644,100 |
kWh
|
$0.042 |
| Electricity Demand | $85,250 | 9,175 |
kW-mo/yr
|
$9.29 |
| Electricity Fees | $8,706 | - |
|
- |
| Natural Gas | $6,772 | 785 |
MMBtu
|
$8.63 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,145 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,515 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,365 | $4,000 |
$1,037
24,617
kWh
|
$328
-
kW-mo/yr
|
|
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $150 | $25 |
$102
2,419
kWh
|
$48
-
kW-mo/yr
|
|
| 03 | 2.7135: Install occupancy sensors | $2,878 | $4,661 |
$2,878
68,292
kWh
|
- | |
| 04 | 2.7228: Avoid introducing hot, humid, or dirty air into hvac system | $1,752 | $4,400 |
$1,203
28,561
kWh
|
$549
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $6,145 | $13,086 |
$5,220
123,889
kWh
|
$925
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $1,515 | $4,025 |
$1,139
27,036
kWh
|
$376
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs