| Assessment Year | 2006 |
|---|---|
| Principal Product | Bakery Mixes |
| NAICS | 311824: Dry Pasta, Dough, and Flour Mixes Manufacturing from Purchased Flour |
| SIC | 2045: Prepared Flour Mixes and Doughs |
| Sales Range | $50 M to 100M |
| # of Employees | 100 |
| Plant Area |
240,000
ft2
|
| Annual Production | 162,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $119,976 | 3,255,369 |
kWh
|
$0.037 |
| Electricity Demand | $71,592 | 7,502 |
kW-mo/yr
|
$9.54 |
| Electricity Fees | $8,210 | - |
|
- |
| Natural Gas | $55,670 | 6,742 |
MMBtu
|
$8.26 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $53,035 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,885 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.6218: Turn off equipment when not in use | $15,410 | $500 |
$10,288
279,190
kWh
|
$5,122
-
kW-mo/yr
|
- | |
| 02 | 2.6231: Utilize controls to operate equipment only when needed | $14,289 | $4,200 |
$14,289
387,764
kWh
|
- | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,355 | $15,984 |
$5,578
151,372
kWh
|
$2,777
-
kW-mo/yr
|
- | |
| 04 | 2.6218: Turn off equipment when not in use | $6,421 | $100 |
$4,287
116,329
kWh
|
$2,134
-
kW-mo/yr
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $1,885 | $2,250 |
$(-97.0)
(-2,632)
kWh
|
$(-46.0)
-
kW-mo/yr
|
$2,028
-
MMBtu
|
|
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,862 | $200 |
$1,862
50,524
kWh
|
- | - | |
| 07 | 2.2437: Recover waste heat from equipment | $1,826 | $1,300 | - | - |
$1,826
-
MMBtu
|
|
| 08 | 2.4221: Install compressor air intakes in coolest locations | $1,622 | $800 |
$1,116
30,307
kWh
|
$506
-
kW-mo/yr
|
- | |
| 09 | 2.4239: Eliminate or reduce compressed air usage | $857 | $300 |
$857
23,266
kWh
|
- | - | |
| 10 | 2.7135: Install occupancy sensors | $508 | $276 |
$508
13,778
kWh
|
- | - | |
| TOTAL RECOMMENDED | $53,035 | $25,910 |
$38,688
1,049,898
kWh
|
$10,493
-
kW-mo/yr
|
$3,854
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,885 | $2,250 |
$(-97.0)
(-2,632)
kWh
|
$(-46.0)
-
kW-mo/yr
|
$2,028
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs