Assessment Year 2005
Principal Product Cardboard Boxes, Plastic Returnable Packaging
NAICS 322211: Corrugated and Solid Fiber Box Manufacturing
SIC 2653: Corrugated and Solid Fiber Boxes
Sales Range $5
M
to 10
M
# of Employees 46
Plant Area 130,000
ft2
Annual Production 92,000,000
thousand feet
Production Hrs. Annual 4,160
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $54,486 1,494,804
kWh
Electricity Demand $51,040 5,326
kW-mo/yr
Electricity Fees $2,396 -
Natural Gas $66,636 8,885
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $26,735 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $16,550

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.7231: Use radiant heater for spot heating $7,943 $12,500 - - $7,943
-
MMBtu
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,268 $11,077 $4,060
110,393
kWh
$3,208
-
kW-mo/yr
-
03 2.7447: Install vinyl strip / high speed / air curtain doors $4,868 $2,650 - - $4,868
-
MMBtu
04 2.7491: Insulate glazing, walls, ceilings, and roofs $2,753 $6,230 - - $2,753
-
MMBtu
05 2.3132: Recharge batteries on during off-peak demand periods $2,242 - - $2,242
-
kW-mo/yr
-
06 2.4221: Install compressor air intakes in coolest locations $1,296 $1,950 $578
15,849
kWh
$718
-
kW-mo/yr
-
07 2.7444: Close holes and openings in building such as broken windows $365 $720 - - $365
-
MMBtu
TOTAL RECOMMENDED $26,735 $35,127 $4,638
126,242
kWh
$6,168
-
kW-mo/yr
$15,929
-
MMBtu
TOTAL IMPLEMENTED $16,550 $22,627 $4,638
126,242
kWh
$3,926
-
kW-mo/yr
$7,986
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs